Doosan E-Powerpack P3A02 cell over voltage fault trouble repair guide.
Related Contents:
Doosan e-Doctor 2.4.0.7 2023.06 100% Work
Doosan Heavy Duty Machine 2020 Service Manual Download
Reason:
Highest cell voltage > 4.25V
Module wire failure
Secondary BMS sensing problem
Effect:
Disable charge
Charge Power(W) = 0
Charge Current(A) = 0
1) Component Location:
<Cell wire>
Damaged somewhere
2) <Secondary BMS>
3) Condition for Running Diagnostic
During charging
4) Condition for Setting the Fault Code
Overcharge or abnormal cell voltage rise(Highest cell voltage > 4.25V)
5) Condition for Clearing the Fault Code
Operate the machine to discharge to the Highest cell voltage ≤ 4.15V
6) How to Solve Doosan E-Powerpack P3A02 cell over voltage
Step 1:
P3A02 is detected on service tool?
Reference value CV_HI>4.25V,Yes go to step 2
Step 2:
Disconnect the battery charger.
Operate the machine to discharge cell voltage in less
than 1 hr. Check the highest cell voltage(CV_HI) via
service tool.
Is P3A02 disappeared?
Reference value CV_HI<4.25V,Problem solved
More topics for Doosan,please refer to:Doosan Trouble Repair
This instruction show you guide on how to remove the threshing drum for CLAAS Lexion…
This instruction show you guide on how to display service menu for Hitachi ZX890-7 excavator.…
Here is the instruction show you guide on how to do Advanced Tool Select and Basic…
Here car-auto-repair.com show you guide on how to solve P1161 trouble code on resistance error…
AGCO EEM Dosing module Description The dosing module (DM) is installed in the exhaust…
Here is the instruction show you guide on how to solve Caterpillar C9 fault code 64-2…