Here comes the solution for Doosan engine P0089 PRV reached maximum allowed opening count.
Preparation:
Doosan Data Monitoring System DMS-5 DMS-3 Free Download
2023 Doosan Diagnostic Tool DDT & G2 Scan Software Free Download
1) Overview
CODE P0089 SPN 520203 FMI 12
REASON
Monitoring the durability of the PRV (Opening time/count of PRV for wear out monitoring)
EFFECT
Torque limit : 0, 1 SVS
2) Circuit Description
Rail Pressure Signal: 236 Pin
Ground: 260 Pin
+5V supply: 211 Pin
3) Component Location
4) Condition for Running Diagnostic
Key on or Engine run
5) Condition for Setting the Fault Code
1. Opening count of PRV is more than 50 times
2. Forced to open the pressure relief valve performing a rail pressure shock according to the ECU logic
3. Forced to open the pressure relief valve performing rail pressure increase
4. PRV opening time is more than 50 times and is running engine for 300min
5. PRV opening time is longer than 300min
6) Condition for Clearing the Fault Code
1. Diagnostic Tester
2. Close the pressure relief valve performing rail pressure decrease
7) Check List
| Step | Inspection | Standard Value | YES | NO |
| 1 | Change PRV(or Common Rail) and reset PRV parameter by DDT |
More topics for Doosan,please refer to:Doosan Trouble Repair
Here is the instruction show you guide on how to replace fuel tank breather filter…
FENDT 900 Vario COM III tractor Component B092 - Sensor, charge air pressure/temperature reports the boost…
Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution Error description…
This instruction show you guide on how to perform hydraulic flow test for Kubota L3301…
This instruction show you guide on how to configure Lane Departure Warning for Bendix AutoVue…
This instruction show you guide on how to solve AGCO machine SPN102 FMI03 boost pressure…