Benz E211 Central Gateway Offline Coding by DAS Xentry

This article show you procedures on DAS Xentry perform Central Gateway offline coding for Mercedes Benz E211.And i wrote Benz module coding projects here:Benz coding,check it to get more tests.

 

Preparations:

Benz DTS Monaco Software Free Download

How to Install Mercedes Benz DTS Monaco Software

VXDIAG Benz/BMW

 

Central Gateway Offline Coding by DAS Xentry:

Run Benz DAS Xentry diagnosis software

After vehicle identification and data reading,select “Quick Test”,then click “F3”

Wait for all modules data determined…

 

Note:It was not possible to automatically read all the values and they must therefore be entered manually.

 

After all control units quick test finish,select “CGW-Central gateway”and click “F3” button to continue

Select “Control unit adaptations”,then click “F3” button

Select “Control module programming”,F3 to continue

In the following procedure,the data of the following modules is programmed in full:

-Central gateway

-System diagnosis

-ASSYST

-ASSYST PLUS

Note:Sufficient voltage must be available throughout the procedure.

Click “F2”

Select “Offline (diagnostic unit not networked)”,click “F3” to continue

The measures to be performed on the vehicle can be supported using the online network connection to the central system or offline.

The “online” process is always recommended.

This ensures that the diagnostic system operates with the current data.

If a network connection is not available,the “offline” process can be used

Data record selection Control module programming

New control unit software versions are available for the following control units:

Control unit Central gateway Estimated programming duration:2 Minutes

Perform control unit programming?

Click “Yes” to continue

Enter the reason for control unit programming:up

Click “F2” to continue

The coding is being read,please wait…

It will reset control unit to original delivery status

Rest of control module is performed.

Control unit Central gateway programming progress,it will take about 2 minutes

Check the notes:

 

The coding is being carried out,please wait

Erase fault memory,please switch on ignition

Central Gateway programming was completed successfully

All input fields must be filled out,then click “F2” to continue

Done!

auto

Recent Posts

Scania Truck ALM 000463 Motion and Inclination Detector,Calibration Fault

This instruction show you guide on how to solve Scania truck motion and inclination detector,…

2 weeks ago

How to Solve JCB Excavator C130C-13 Spool Brake Solenoid Open Circuit

This instruction show you guide on how to solve JCB excavator 140 C130C-13 spool brake solenoid…

2 weeks ago

Scania Truck ALM Alarm System ALM404 Fault in the CAN Communication Solution

Scania truck fault in the CAN communication with the chassis management system (CMS),this instruction show…

4 weeks ago

Perkins Phaser/1000 Series Engine New Water Pumps Changed

The water pumps used on all Phaser/1000 Series engines have been changed. The changes to…

4 weeks ago

Deutz Engine EMR3 Request of Engine OFF Error Solution

Here is the simple instruction on how to solve Deutz engine EMR3 trouble code 48…

1 month ago

How to Use Cat ET 2025A Power Shift Pressure Test Function?

CAT ET 2025A Power Shift Pressure Test function checks whether that the proportional reducing valve is…

1 month ago