Preparations:

Benz DTS Monaco Software Free Download

How to Install Mercedes Benz DTS Monaco Software

VXDIAG Benz/BMW

 

Central Gateway Offline Coding by DAS Xentry:

Run Benz DAS Xentry diagnosis software

After vehicle identification and data reading,select “Quick Test”,then click “F3”

Wait for all modules data determined…

 

Note:It was not possible to automatically read all the values and they must therefore be entered manually.

 

After all control units quick test finish,select “CGW-Central gateway”and click “F3” button to continue

Select “Control unit adaptations”,then click “F3” button

Select “Control module programming”,F3 to continue

In the following procedure,the data of the following modules is programmed in full:

-Central gateway

-System diagnosis

-ASSYST

-ASSYST PLUS

Note:Sufficient voltage must be available throughout the procedure.

Click “F2”

Select “Offline (diagnostic unit not networked)”,click “F3” to continue

The measures to be performed on the vehicle can be supported using the online network connection to the central system or offline.

The “online” process is always recommended.

This ensures that the diagnostic system operates with the current data.

If a network connection is not available,the “offline” process can be used

Data record selection Control module programming

New control unit software versions are available for the following control units:

Control unit Central gateway Estimated programming duration:2 Minutes

Perform control unit programming?

Click “Yes” to continue

Enter the reason for control unit programming:up

Click “F2” to continue

The coding is being read,please wait…

It will reset control unit to original delivery status

Rest of control module is performed.

Control unit Central gateway programming progress,it will take about 2 minutes

Check the notes:

 

The coding is being carried out,please wait

Erase fault memory,please switch on ignition

Central Gateway programming was completed successfully

All input fields must be filled out,then click “F2” to continue

Done!

auto

Recent Posts

How to Remove and Replace Cab Heater Controls for JCB 3CX Loader

Here is the instruction show you guide on how to remove and replace cab heater…

3 weeks ago

How to Remove Differential Gear for FENDT 900 Vario COMIII

Here is the instruction show you guide on how to remove differential gear for Fendt…

3 weeks ago

International MaxxForce 7 SPN 27 FMI 4 EGRP Signal Out of Range Low

This instruction show you guide on how to solve International MaxxsForce 7 SPN 27 FMI…

4 weeks ago

2025.08 BMW ISTA 4.54.40/4.02.14 ISTA-D Rheingold for BMW ICOM

BMW ISTA-D Rheingold 4.54.40/4.02.14 Standalone / SDP 4.02.13 / ISTA-P 3.60.0.600 free download link and…

4 weeks ago

Detroit DD13 SPN 84 FMI 3 MCM Vehicle Speed Sensor Open Circuit

This instruction show you guide on how to solve Detroit DD13 engine SPN 84 FMI…

4 weeks ago

How to Solve Caterpillar 24 PID 100-3 Oil Pressure Voltage High?

This instruction show you guide on how to repair Caterpillar 24 fault code,PID 100-3 oil…

1 month ago