Bendix EC-80 Cartridge Lifetime Prediction Reset Test by JPRO

Here is the instruction show you guide on how to perform Cartridge lifetime prediction reset for Bendix EC-80 by JPRO Diagnostic Software.This test provides the ability to reset the Cartridge Lifetime Remaining value to 100% after a new air dryer cartridge has been installed.

 

Related Contents:

2024 JPRO Noregon Commercial Fleet Diagnostics Free Download

Noregon JPRO DLA+ 2.0 Adapter

 

Procedures:

1 Select Cartridge Lifetime Prediction Reset Test and press Enter or the Start Button.

2 The test dialog will be displayed.

NOTE: Reset should only be performed after a new air dryer cartridge has been installed.
3 Click the Reset button to reset the Cartridge Lifetime Remaining value to 100%. The Wetness Level and Total Air Delivered values will also be reset.
4 Selecting Additional Info will display important test and repair information, including explanations for related faults. Click Exit to close this screen.

 

Cartridge Lifetime Prediction Reset Information:

The CLP Reset should only be performed after a new air dryer cartridge has been installed. Resetting the CLP without changing the cartridge can lead to moisture and water in air system.

Cartridge Lifetime Remaining (SPN 13073) indicates between 100% for a fresh cartridge to 0% for

an expired cartridge. After CLP Reset is performed, Cartridge Lifetime Remaining will read 100%.

 

For specific instructions, see AD-HFi Service Data Sheet SD-08-12046.

The following faults are the ones related to Cartridge Lifetime Prediction and the actions to take:

Cartridge maintenance prediction pre-worn alert (Flash Code 30-1), SPN 521610, FMI 15:

This indicates the cartridge is approaching its lifetimne limit (15% lifetimne remaining or less).

Cartridge may be replaced and CLP Reset run.

 

Cartridge maintenance prediction nominal alert (Flash Code 30- 2), SPN 52610, FMI 16:

This indicates the cartridge has reached its lifetime limit or 0% lifetime remaining. Cartridge must be replaced and CLP Reset run.

 

Cartridge maintenance prediction over-worn alert (Flash Code 30-3), SPN 521610, FMI 0:

This indicates that the cartridge has been in service beyond its service lifetime. This fault also

indicates there may be water in the air system. Check reservoirs for water via drain check valves and service accordingly. Cartridge must be replaced and CLP Reset run.

 

5 When done, press the Exit button to return to the test selection dialog.

More topics about JPRO Diagnostic,please refer to:JPRO Diagnostics Guide

auto

Recent Posts

AGCO EEM5 DEF Suction Module Tank sensor (CAN)

AGCO EEM5 DEF Suction Module Tank sensor (CAN) The DEF suction module with the CAN-bus…

11 hours ago

How to Remove Threshing Drum for CLAAS Lexion 480 Combine

This instruction show you guide on how to remove the threshing drum for CLAAS Lexion…

2 days ago

Hitachi ZX890-7 Excavator Service Menu Display

This instruction show you guide on how to display service menu for Hitachi ZX890-7 excavator.…

5 days ago

JCB 200 Series Excavator ATS Setup and Calibration Procedure

Here is the instruction show you guide on how to do Advanced Tool Select and Basic…

1 week ago

How to Solve Liebherr D966 D9512 Trouble Code P1161 Resistance Error

Here car-auto-repair.com show you guide on how to solve P1161 trouble code on resistance error…

2 weeks ago

AGCO EEM 5 Dosing Module

AGCO EEM Dosing module   Description The dosing module (DM) is installed in the exhaust…

2 weeks ago