This instruction show you guide on how to reset airbag crash data for Tesla Model 3 by Launch X431.

 

This function is used to reset airbag crash data in order to recycle airbag ECU (Electric Control Unit). (In some countries, erasing airbag crash data without changing airbag assembly is not legal. So, we highly recommend to replacing car’s entire airbag assembly).

 

Preparations:

Launch X431 V Pro or Launch X431 PAD V (Amazon Official Shop)

 

Procedures:

Preparation (For some Model 3 vehicle, there’s no need to remove airbag ECU. If OBDII can communicate normally, please skip this procedure)

Remove airbag ECU from vehicle

Airbag ECU connection position

Airbag ECU wiring diagram

Wiring and pin allocation

+12V: 12V power supply

GND: Ground wire

CAN_H: CAN high

CAN_L: CAN low

Tesla airbag repair designated connector wiring diagram

 

Resetting airbag crash data software operation procedure

Go into Tesla software, select”Model 3″ ->”Special Function” -> “Service AIRBAG” ,as shown in figure 1, or select”Model 3″ -> “System Selection” –> “SDM Airbag” -> “Special Function”

 

Unlock airbag ECU, click” Unlock EEPROM After Crash” . It will finish automatically.

Read airbag ECU memory, select “Read EEProm” menu, when reading is done, input backup file name, select backup file storage directory, data backup is done.

Input backup file name, for example “Model_3_20210520”

Click “OK”to backup data.

Read EEPROM and backup finished

Erase crash data, go into ” Erase Crash -Direct” menu, select ” Read EEProm”  backup file. The software will automatically perform ” Write EEProm”  to write backup data and verify if data written is correct.

Select backup file

Click “Model_3_20210520.bin” to select back file

Edit backup data. Press” YES”  to use default data. Press ” Auto Set”  to automatically modify value (recommended). Press ” Memory Dump”  to manually modify backup data.

if you press ” Auto Set” , it will skip this procedure. Press ” Memory Dump” , you can manually modify backup data. Start address is where the system starts to read backup data and it can be modified manually. After entering start address, press ” Confirm”  to write modified data, click ” Restore”  to recover it to old value.

Write data, erase airbag crash data.

 

Verify written data

Write crash data, go into “Write EEProm” menu, select backup file. The software will automatically write backup data and verify if data is correct. This procedure is similar to above mentioned procedure “Erase Crash -Direct” .

Select backup file

Click “Model_3_20210520.bin” to select back file

Edit backup data. Press“YES”to use default data. Press “Auto Set” to automatically modify value (recommended). Press “Memory Dump” to manually modify backup data.

Write Data

Verify written backup data

Erase crash record, go into”Erase Crash Record” menu, the software will automatically finish it.

Clear DTC (Diagnostic Trouble Code), put airbag ECU back. Erasing crash data is done.

If you find the above procedure is cumbersome, please click ” Crash Data Resetting Automatically”  menu, it will automatically perform all procedures.

More test report about Launch X431 please check:Launch X431 Test report

auto

Recent Posts

Valtra BH Series 140-210 Trouble Internal Roll inertial Sensor Fault

This instruction show you guide on how to solve Valtra BH Series 140-210 trouble code SA…

5 days ago

Caterpillar C9 Engine Throttle Position Out of Calibration 28 91-13 Trouble Solution

This instruction show you guide on how how to solve trouble code 28 PID 91-13…

1 week ago

Magneti Marelli 1 AVB-VW ECU Pinout

Vehicles: With AP 1.6, 1.8 and 2.0 Ml engines DE 97 to 99. And for…

1 week ago

Valtra BH Series 140-210 Internal lateral Inertial Sensor Recalibration

This instruction show you guide on how to solve Valtra BH Series 140-210 trouble code SA…

2 weeks ago

Bendix AutoVue 3G LDW System Driver Assistance Systems (DAS) Tests

JPRO 2025V3 Driver Assistance Systems (DAS) Tests allows the editing of configuration parameters.   Related Contents:…

2 weeks ago

How to Solve PCC2300 PowerCommand Membrane Buttons Not Functioning

This instruction show you guide on how to solve PCC2300 Powercommand Membrane buttons not working.…

3 weeks ago