Heavy Equipment Repair

JCB Tier 4 Engine Start Relay High Side Voltage and Current Above Normal

Here is the instruction show you guide on how to solve JCB Tier 4 engine SPN 1321, FMI 3 and SPN 1321, FMI 6 start reply high side voltage/current above normal.

Related Contents:

WinEEM4s JCB Service Tool 2.7.2 2.6.1 Free Download

2024 JCB ServiceMaster 4 v24.6.2 Free Download for Win 10 Win11

2017 JCB Parts Plus+ and Repair Service Manual Free Download

 

 

Start Relay High Side Voltage Above Normal

Description

The start relay high side voltage is above the normal operating range.

 

Possible causes are:

The start relay wiring is defective.

The start relay is defective

 

Reaction in EEM

The FC is stored and the warning lamp is activated. The CAN message indicates active fault.

 

Solution

First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:

Check the start relay wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).

Check the operation with another start relay to see if the relay is defective.

 

 

Start Relay High Side Current Above Normal

Description

The start relay high side current is above the normal operating range.

 

Possible causes are:

The start relay wiring is defective.

The start relay is defective

 

Reaction in EEM

The FC is stored and the warning lamp is activated. The CAN message indicates active fault.

 

Solution

First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:

Check the start relay wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).

Check the operation with another start relay to see if the relay is defective.

More repair case for JCB,please refer to:JCB Trouble Repair

auto

Recent Posts

Scania Truck ALM 000463 Motion and Inclination Detector,Calibration Fault

This instruction show you guide on how to solve Scania truck motion and inclination detector,…

1 week ago

How to Solve JCB Excavator C130C-13 Spool Brake Solenoid Open Circuit

This instruction show you guide on how to solve JCB excavator 140 C130C-13 spool brake solenoid…

2 weeks ago

Scania Truck ALM Alarm System ALM404 Fault in the CAN Communication Solution

Scania truck fault in the CAN communication with the chassis management system (CMS),this instruction show…

4 weeks ago

Perkins Phaser/1000 Series Engine New Water Pumps Changed

The water pumps used on all Phaser/1000 Series engines have been changed. The changes to…

4 weeks ago

Deutz Engine EMR3 Request of Engine OFF Error Solution

Here is the simple instruction on how to solve Deutz engine EMR3 trouble code 48…

1 month ago

How to Use Cat ET 2025A Power Shift Pressure Test Function?

CAT ET 2025A Power Shift Pressure Test function checks whether that the proportional reducing valve is…

1 month ago