Categories: Do It YouselfHow To

How to Use Scania XCOM Clear/Reset Memory Areas

This instruction show ou guide on how to use Scania XCOM software to reset/clear memory areas.And please follow below operations:

 

Preparations:

Scania XCOM V2.30 V2.27 Dongle Emulator Free Download

How to Install Scania XCOM V2.30 Diagnostic Software

 

Steps:

1) Connect to CAN (see use case “Connect to CAN”)

2) Open the ”Clear” form for the related ECU. This is done either by expanding the ECU node in explorer tree and double clicking on the ”Clear” function/data node or by selecting the menu choice ECUs->(the EcuName)->Clear. The Configuration form is displayed. Example:

3) Select the area that is to be programmed by making the check mark visible for the name of the area in the list box.

4) Press the ”Clear selected areas” button to reset the data area.

5) When the button is pushed a dialog is displayed to confirm the operation:

6) Press ”Yes” to start the reset sequence. An ECU reset will be performed when the clear is done.

7) When the sequence is complete a dialog is displayed to report the result:

 

DCMN memory area

To clear (reset) DCMN data areas, perform the following steps.

1) Connect to CAN (see use case “Connect to CAN”) if not already connected.

2) Open the ”Duty Cycle Data” form for the related ECU. This is done either by expanding the ECU node in explorer tree and double clicking on the ”Duty Cycle Data” function/data node or by selecting the menu choice ECUs->(the EcuName)->Duty Cycle Data. The ”Duty Cycle Data” form is displayed

3) Select the areas that are to be cleared by putting the check mark in the boxes of the names in the list box.

4) Clear the areas by pressing the ”Reset” button.

5) The application will erase the areas and display the result in the main form”s status window.

6) The sequence is now complete

 

OPC4/RET1 statistic tables

To clear the OPC/RET statistics tables, perform the following steps.

1) Connect to CAN (see use case “Connect to CAN”) if not already connected.

2) Open the ”Statistics” form for the a OPC or RET.

3) Click the “Clear statistics tables” to clear the tables.

4) A query dialog will be displayed to confirm the action.

5) Press ‘Yes’ to proceed and ‘No’ to abort the sequence.

6) The result of the action is displayed in the main form’s status window.

7) The sequence is now complete.

 

auto

Recent Posts

Scania Truck ALM 000463 Motion and Inclination Detector,Calibration Fault

This instruction show you guide on how to solve Scania truck motion and inclination detector,…

2 weeks ago

How to Solve JCB Excavator C130C-13 Spool Brake Solenoid Open Circuit

This instruction show you guide on how to solve JCB excavator 140 C130C-13 spool brake solenoid…

2 weeks ago

Scania Truck ALM Alarm System ALM404 Fault in the CAN Communication Solution

Scania truck fault in the CAN communication with the chassis management system (CMS),this instruction show…

4 weeks ago

Perkins Phaser/1000 Series Engine New Water Pumps Changed

The water pumps used on all Phaser/1000 Series engines have been changed. The changes to…

4 weeks ago

Deutz Engine EMR3 Request of Engine OFF Error Solution

Here is the simple instruction on how to solve Deutz engine EMR3 trouble code 48…

1 month ago

How to Use Cat ET 2025A Power Shift Pressure Test Function?

CAT ET 2025A Power Shift Pressure Test function checks whether that the proportional reducing valve is…

1 month ago