Here is the instruction show yo guide on how to solve Fendt MT800E tractor DEF tank temperature does not change during the heating cycle.
Preparations:
Code SA 00 SPN 3031 FMI 10
The DEF tank temperature does not change during the heating cycle.
Diagnosis and solution
Clear the error log.
Restart the engine module.
If the fault code shows again during the next driving cycle, check the following.
Check the coolant supply of the tank heating element.
Install a new DEF tank heating valve to see if the original is bad.
Check the DEF tank temperature sensor harness. Make sure the connections are good and the contacts are clean.
Replace the DEF tank temperature sensor. If the system is correct and the fault code is not active, the original sensor is bad.
If you want more repair cases for Fendt tractor,please refer to Fendt Tractor Trouble Repair
This instruction show you guide on how to solve Scania truck motion and inclination detector,…
This instruction show you guide on how to solve JCB excavator 140 C130C-13 spool brake solenoid…
Scania truck fault in the CAN communication with the chassis management system (CMS),this instruction show…
The water pumps used on all Phaser/1000 Series engines have been changed. The changes to…
Here is the simple instruction on how to solve Deutz engine EMR3 trouble code 48…
CAT ET 2025A Power Shift Pressure Test function checks whether that the proportional reducing valve is…