Heavy Equipment Repair

Allison 3000 & 4000 Gen5 Transmission Range Sensor Circuit High

This instruction show you guide on how to repair Allison 3000 & 4000 Gen5 fault code P0708 transmission range sensor circuit high.

 

Related Contents:

2023 Diesel DTC Solutions V2.9.98+ Diesel Explorer 2.0+Instruction

2024 2019 Allison DOC Transmission Diagnostic Software Free Download

 

 

DIAGNOSTIC RESPONSE:

Ignore defective strip selector inputs

 

CIRCUIT DESCRIPTION:

This test monitors whether the transmission range data from the analog strip shift selector is valid.

 

ACTION TAKEN WHEN THE DTC SETS:

When the DTC P0708 is active, the following conditions occur:

1 The DTC is stored in the TCM history.

2 The TCM illuminates the CHECK TRANS light.

3 The TCM ignores input from the analog strip shift selector.

4 Locks in N (Neutral).

 

CONDITIONS FOR CLEARING THE DTC/CHECK TRANS LIGHT:

Use the diagnostic tool to clear the DTC from the TCM history. The TCM automatically clears the DTC from theTCM history if the vehicle completes 40 warm-up cycles without the DTC recurring.

 

DIAGNOSTIC AIDS:

This DTC may be caused by:

1 Short to power or short to another wire in W114,W138,W153, or W173.

2 High resistance or open in W114, W138,W153, or W173.

3 Poor yehicle grounds.

4 Unlocked connectors, expanded terminals, poor pin crimps or unlocked pins causing high resistance or open circuit.

5 Unlocked connectors, unlocked pins, causing shorts in connectors.

6 TCM ground is at different voltage potential than the ground of the OEM voltage source responsible for strip shift selector.

7 Defective TCM.

8 Defective strip shift selector.

More Allison repair case,please refer to Allison Trouble Repair

auto

Recent Posts

How to Remove and Replace Cab Heater Controls for JCB 3CX Loader

Here is the instruction show you guide on how to remove and replace cab heater…

3 weeks ago

How to Remove Differential Gear for FENDT 900 Vario COMIII

Here is the instruction show you guide on how to remove differential gear for Fendt…

3 weeks ago

International MaxxForce 7 SPN 27 FMI 4 EGRP Signal Out of Range Low

This instruction show you guide on how to solve International MaxxsForce 7 SPN 27 FMI…

4 weeks ago

2025.08 BMW ISTA 4.54.40/4.02.14 ISTA-D Rheingold for BMW ICOM

BMW ISTA-D Rheingold 4.54.40/4.02.14 Standalone / SDP 4.02.13 / ISTA-P 3.60.0.600 free download link and…

4 weeks ago

Detroit DD13 SPN 84 FMI 3 MCM Vehicle Speed Sensor Open Circuit

This instruction show you guide on how to solve Detroit DD13 engine SPN 84 FMI…

4 weeks ago

How to Solve Caterpillar 24 PID 100-3 Oil Pressure Voltage High?

This instruction show you guide on how to repair Caterpillar 24 fault code,PID 100-3 oil…

1 month ago