Wabco D Version Hydraulic ABS Sensor Output Voltage Test

Sensor output voltage must be at least 0.2 volts AC at 30 rpm. Test the sensor output voltage as follows:

1.Turn ignition OFF.

2.Disconnect the ECU. To measure voltage at the pins on the ECU connector, disconnect thesensor from the sensor extension cable.

 

Related Contents:

Meritor Wabco Toolbox v13.6 v12 Diagnostic Software Download

 

WARNING

Block the wheels to prevent the vehicle from moving. Support the vehicle with safety stands.

Do not work under a vehicle supported only by jacks. Jacks can slip and fall over. Serious personal injury can result.

3.Put blocks under the front and rear tires to stop the vehicle from moving.

4.Raise the vehicle off the ground. Put safety stands under the axle.

5.Rotate wheel by hand at 30 rpm (1/2 revolution per second).

6.Measure the voltage at the pins indicated in Table F.

 

Sensor Resistance

The sensor circuit resistance must be between 900 and 2000 ohms. Measure resistance at the sensor connector, or at the pins on the ECU connector,as follows:

1.Turn ignition OFF.

2.To measure resistance at the pins on ECU connector, disconnect the ECU connector from the ECU.

To measure resistance at the sensor connector, disconnect the sensor from the sensor extension cable.

3.Measure output at the pins indicated in Table F, Sensor Check Pins.

If measurement is not between 900 and 2000 ohms, replace the sensor.

auto

Recent Posts

Scania Truck ALM 000463 Motion and Inclination Detector,Calibration Fault

This instruction show you guide on how to solve Scania truck motion and inclination detector,…

2 weeks ago

How to Solve JCB Excavator C130C-13 Spool Brake Solenoid Open Circuit

This instruction show you guide on how to solve JCB excavator 140 C130C-13 spool brake solenoid…

2 weeks ago

Scania Truck ALM Alarm System ALM404 Fault in the CAN Communication Solution

Scania truck fault in the CAN communication with the chassis management system (CMS),this instruction show…

4 weeks ago

Perkins Phaser/1000 Series Engine New Water Pumps Changed

The water pumps used on all Phaser/1000 Series engines have been changed. The changes to…

4 weeks ago

Deutz Engine EMR3 Request of Engine OFF Error Solution

Here is the simple instruction on how to solve Deutz engine EMR3 trouble code 48…

1 month ago

How to Use Cat ET 2025A Power Shift Pressure Test Function?

CAT ET 2025A Power Shift Pressure Test function checks whether that the proportional reducing valve is…

1 month ago