Perkins 1106D engine overspeed error always caused by speed above the trip point of overspeed.Here is the guide on how to solve Perkins 1106D generation E362 engine overspeed error.
Preparations:
Perkins EST 2024A & 2023A & 2019A Software Free Download
Perkins SPI2 2018A EPC+Service Manual Free Download
Perkins Communication Adapter 3
Conditions Which Generate This Code:
The engine speed is above the trip point for engine overspeed. Refer to Table.
Note: This event code represents an event. This does not represent an electronic system fault.
Note: The electronic service tool can be used to change the trip points for engine overspeed.
System Response:
The event code will be logged.
The event may be viewed by using a display module or by using the electronic service tool.
Possible Performance Effect:
E362-1
The warning lamp will be illuminated and the diagnostic lamp will flash the event code.
The fuel injection will be switched OFF until the engine speed drops below the trip point by 200 RPM.
E362-3
The warning lamp and the shutdown lamp will be illuminated and the diagnostic lamp will flash the event code.
If the “Enable Shutdown” parameter is enabled, the engine will be shut down.
This event indicates excessive engine speed. This event does not represent a fault in the Electronic Control Module (ECM).
This event does not represent a fault in a speed/timing sensor.
No troubleshooting is required.
Results:
• OK – STOP
More trouble repair case for Perkins,pls refer to:Perkins Trouble Repair
This instruction show you guide on how to solve Scania truck motion and inclination detector,…
This instruction show you guide on how to solve JCB excavator 140 C130C-13 spool brake solenoid…
Scania truck fault in the CAN communication with the chassis management system (CMS),this instruction show…
The water pumps used on all Phaser/1000 Series engines have been changed. The changes to…
Here is the simple instruction on how to solve Deutz engine EMR3 trouble code 48…
CAT ET 2025A Power Shift Pressure Test function checks whether that the proportional reducing valve is…