Perkins 1106D Electric Power Generation CID 0172 FMI 03 Guide

Conditions Which Generate This Code:
The Electronic Control Module (ECM) detects the following conditions:
• The signal voltage from the intake manifold air temperature sensor is greater than 4.95 Volts DC
for more than eight seconds.
• Engine coolant temperature is above -10 °C (15.0 °F).
• The ECM has been powered for at least two seconds.
• Diagnostic code 0168-01 is not active.

Preparations:

Perkins EST 2024A & 2023A & 2019A Software Free Download

Perkins SPI2 2018A EPC+Service Manual Free Download

Perkins Communication Adapter 3

 

System Response:
If equipped, the diagnostic lamp will flash. The ECM will log the diagnostic code.
The ECM will use the default value of 70 °C (158 °F) for the intake manifold air temperature. “Voltage High” will be displayed next to the status for “Intake Manifold Air Temperature” on the electronic service tool.

Possible Performance Effect:
• Poor stability
• Poor cold running
• White smoke
• Black smoke
• Poor acceleration under load

Troubleshooting:
This fault can be caused by an open circuit or a short to a power source.
Perform the following diagnostic procedure: “Engine Temperature Sensor Open or Short Circuit – Test”

Results:
• OK – STOP

 

More trouble repair case for Perkins,pls refer to:Perkins Trouble Repair

auto

Recent Posts

Scania Truck Direction Indicator Front Right CUV 5 Trouble Repair

Here is the instruction show you guide on how to solve Scania truck direction indicator…

2 days ago

How to Solve CAT C9 Engine 8 Volt Supply Voltage High Problem

This instruction show you guide on how to solve Caterpillar C9 engine 8 volt supply…

1 week ago

How to Replace HV Battery ECU for HINO Truck J05E Engine

This instruction show you guide on how to remove and install HV Battery ECU for…

2 weeks ago

Scania Truck CAN Communicatinon Fault Engine Control Unit Error Solution

This instruction show you guide on how to solve CAN communication engine control unit error…

2 weeks ago

Caterpillar C9 Engine Injection Actuation Pressure Output Fault Solution

This instruction show you guide on how to solve Caterpillar C9 engine injection actuation pressure…

3 weeks ago

How to Remove HV Battery Cooling FAN for HINO Truck with J05E Engine

Here is the instruction show you guide on how to remove HV battery cooling fan…

4 weeks ago