Heavy Equipment Repair

PCC1302 PowerCommand Code 1847 Engine Coolant Temperature High

This illustration show you guide on how to solve PCC1302 PowerCommand trouble code 1847 engine coolant temperature high shutdown with cooldown.

Related Contents:

2024 InPower V14.5 Pro V12 Diagnostic Software Free Download

PowerCommand Diagnostic 9 Pin Adapter Cable for InPower

 

Logic:
Exhaust gas temperature sensor signal is out of range – shorted high.

Possible Causes:
1 Inaccurate engine temperature sensor
2 Fault simulation feature is enabled
3 Threshold setting too low

 

Diagnosis and Repair:
1 Inaccurate engine temperature sensor
a Verify the sensor accuracy with a thermocouple or similar temperature probe.
a Connect the temperature probe to the engine near the coolant temperature sensor.
b Connect InPower.
c Compare the coolant temperature reading on the service tool monitor screen to the reading from the temperature probe. If the two readings are reasonably close, then the sensor is reading correctly.

2 Fault simulation feature is enabled
a Verify that the fault simulation feature for the sensor is not enabled.
a Connect InPower.
b Verify that the fault simulation is not enabled for the coolant temperature sensor by connecting to the PCC via InPower. If the fault simulation is disabled, there is no problem.

3 Threshold setting too low
a Check threshold settings.
a Connect InPower.
b Verify that fault threshold is within the normal operating range for the coolant temperature sensor. Refer to the engine manual for correct threshold values and make the appropriate changes using InPower.

auto

Recent Posts

Scania Truck ALM 000463 Motion and Inclination Detector,Calibration Fault

This instruction show you guide on how to solve Scania truck motion and inclination detector,…

2 weeks ago

How to Solve JCB Excavator C130C-13 Spool Brake Solenoid Open Circuit

This instruction show you guide on how to solve JCB excavator 140 C130C-13 spool brake solenoid…

2 weeks ago

Scania Truck ALM Alarm System ALM404 Fault in the CAN Communication Solution

Scania truck fault in the CAN communication with the chassis management system (CMS),this instruction show…

4 weeks ago

Perkins Phaser/1000 Series Engine New Water Pumps Changed

The water pumps used on all Phaser/1000 Series engines have been changed. The changes to…

4 weeks ago

Deutz Engine EMR3 Request of Engine OFF Error Solution

Here is the simple instruction on how to solve Deutz engine EMR3 trouble code 48…

1 month ago

How to Use Cat ET 2025A Power Shift Pressure Test Function?

CAT ET 2025A Power Shift Pressure Test function checks whether that the proportional reducing valve is…

1 month ago