Here is an instruction show you guide on how to adjust the sensors on the rack collision protection system for Linde R1120-1 forklift truck.
Preparations:
2023 Linde Service Guide LSG 5.2.2 U0278 and 5.1.2 Free Download
Description
Linde MH has been informed that the light point spacing between the sensors of the rack collision protection system is too large for some loads.
Course of action
1 Standard (sensor in the outer position) = 1216 mm
2 Narrow loads (sensor in the inner position) = 1076 mm
For smaller loads, the sensors of the rack collision protection system can be rotated by 180°. This reduces the light point spacing.
For smaller loads, the sensors of the rack collision protection system can be rotated by 180°. This reduces the light point spacing.
Standard
Sensor in the outer position (1)
Light point spacing: 1216 mm
Narrow loads
Sensor in the inner position (2)
Light point spacing: 1076 mm
Comment
If the customer’s existing trucks have already been fitted with a rack collision protection system with a narrow sensor cut-out, the sensor supports can be modified with the following rework:
R14 – R16
R20 – R25
Comment
This Service Information describes a technical change and a problem that may arise in the field. It is not an instruction for a general modification or repair. The information contained within this Service Information does not provide the basis for any warranty claim.
More service information,please refer to:Linde Forklift Truck Repair
This instruction show you guide on how to solve Bobcat engine DCU P1A32 Self-Diagnostis in…
How to Use Hyster Yale PC Service Tool Password Management Function Note: To access…
When you use IDSS diagnostic scan to do some function,it may occur communication error.Sometime you…
Deutz engine EOL test (end of line) is required to ensure the EAT functionality. Conditions…
This instruction show you guide on how to solve Scania truck articulation control system ACS…
Magneti Marelli 49FB – Fiat ECU Pinout More ECU PINOUT Components: ECU Modules Repair…