Here is an instruction show you guide on how to adjust the sensors on the rack collision protection system for Linde R1120-1 forklift truck.
Preparations:
2023 Linde Service Guide LSG 5.2.2 U0278 and 5.1.2 Free Download
Description
Linde MH has been informed that the light point spacing between the sensors of the rack collision protection system is too large for some loads.
Course of action
1 Standard (sensor in the outer position) = 1216 mm
2 Narrow loads (sensor in the inner position) = 1076 mm
For smaller loads, the sensors of the rack collision protection system can be rotated by 180°. This reduces the light point spacing.
For smaller loads, the sensors of the rack collision protection system can be rotated by 180°. This reduces the light point spacing.
Standard
Sensor in the outer position (1)
Light point spacing: 1216 mm
Narrow loads
Sensor in the inner position (2)
Light point spacing: 1076 mm
Comment
If the customer’s existing trucks have already been fitted with a rack collision protection system with a narrow sensor cut-out, the sensor supports can be modified with the following rework:
R14 – R16
R20 – R25
Comment
This Service Information describes a technical change and a problem that may arise in the field. It is not an instruction for a general modification or repair. The information contained within this Service Information does not provide the basis for any warranty claim.
More service information,please refer to:Linde Forklift Truck Repair
Here is the instruction show you guide on how to replace fuel tank breather filter…
FENDT 900 Vario COM III tractor Component B092 - Sensor, charge air pressure/temperature reports the boost…
Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution Error description…
This instruction show you guide on how to perform hydraulic flow test for Kubota L3301…
This instruction show you guide on how to configure Lane Departure Warning for Bendix AutoVue…
This instruction show you guide on how to solve AGCO machine SPN102 FMI03 boost pressure…