This instruction show you guide on how to perform hydraulic flow test for Kubota L3301 L3901 tractor.
IMPORTANT
Related Contetns:
2025 Kubota Takeuchi Diagmaster v22.08.01 v4.1.2 Software Free Download
Kubota DST-i Diagnostic Adapter
Kubota EPC Spare Parts Catalogue 2021.06 Download
Procedures:
1 Remove the power steering delivery pipe or delivery hose joint
bolt and install the pump adaptor 2 to the pump discharge port.
2 Connect the hydraulic test hose to the pump adaptor 2 and flowmeter inlet port.
3 Connect the other hydraulic test hose to the flowmeter outlet port and to transmission fluid filling plug hole.
4 Open the flowmeter loading valve completely. (Turn counterclockwise.)
5 Start the engine and set the engine speed at 2000 to 2200 min-1 (rpm).
6 Slowly close the loading valve to generate pressure approx. 9.81 MPa (100 kgf/cm2 , 1420 psi). Hold in this condition until oil temperature reached approx. 40 °C (104 °F).
7 Open the loading valve completely.
8 Set the engine speed. (Refer to Condition.)
9 Read and note the pump delivery at no pressure.
10 Slowly close the loading valve to increase pressure (Rated pressure). As the load is increased, engine speed drops,therefore, reset the engine speed.
11 Read and note the pump delivery at rated pressure.
12 Open the loading valve completely and stop the engine.
13 If the pump delivery does not reach the allowable limit, check the pump suction line, oil filter or hydraulic pump. (When reassembling)
More repair case for Kubota,please refer to:Kubota Trouble Repair
This instruction show you guide on how to configure Lane Departure Warning for Bendix AutoVue…
This instruction show you guide on how to solve AGCO machine SPN102 FMI03 boost pressure…
Here is the instruction show you guide on how to solve Scania Truck ATA 152…
This instruction show you guide on how to solve Valtra BH Series 140-210 trouble code SA…
This instruction show you guide on how how to solve trouble code 28 PID 91-13…
Vehicles: With AP 1.6, 1.8 and 2.0 Ml engines DE 97 to 99. And for…