Heavy Equipment Repair

JCB Backhoe Loader 3X/4X/5X B00B729 Seat Switch Signals Disagreement Solution

Here is the instruction show you guide on how to repair JCB backhoe loader 3X/4X/5X B00B729 seat switch signals disagreement.

 

Related Contents:

WinEEM4s JCB Service Tool 2.7.2 2.6.1 Free Download

2024 JCB ServiceMaster 4 v24.6.2 Free Download for Win 10 Win11

2017 JCB Parts Plus+ and Repair Service Manual Free Download

 

DTC-FTB Description

Seat Switch Signals Disagreement

 

Information

 

Service Procedure

Important: Stop the engine and let it cool before you start work. Do not start the engine during the service procedures. (SN0001)

1 Check for any debris or water inside the connector terminals. This may be as a consequence of pressure washing, loose connectors or poor connector sealing.

2 Check the harness is not damaged and is routed correctly.

3 Check seat harness for correct fitment.

4 The signal may also be checked using ServiceMaster. Switch ignition ON and using Servicemaster BHL machine diagnostics tool, navigate to tab 3.11 ‘Seat Position Status’.

5 There is a disagreement if there is input from both J1-08 and J2-03.

More repair case for JCB,please refer to:JCB Trouble Repair

 

auto

Recent Posts

How to Remove Second Tank for CLAAS AXION 960-920 Tractor

This instruction show you guide on how to remove second tank for CLAAS AXION 960-920…

2 days ago

Doosan Excavator P0408 Maximum EGR Rate Governor Deviation Error Solution

This instruction show you guide on how to solve Doosan excavator P0408 maximum EGR rate…

5 days ago

How to Calibrate 2403 Steering Valve for Fendt 800 S4 Tractor

Here is the instruction show you guide on how to calibrate 2403 steering valve for…

1 week ago

Massey Ferguson Tractor Electrohydraulic Spool Valves Configuration

This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You…

1 week ago

How to Remove Center Joint and Center Frame for HITACHI Hitachi EX5600-7B

This instruction show you guide on how to remove center joint and center frame for…

2 weeks ago

How to Repair Doosan Machine P0100 DTC Signal Error

How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…

3 weeks ago