Eaton Heavy Duty Transmission TRSM1500 Shift Bar Housing Installation Guide

This instruction show the guide on how to install shift bar housing for Eaton heavy duty transmission TRSM1500.There are three (3) sizes of Cap Screws. The 1 1/2″ Cap Screws are used with the Lifting Eyes. The 1 1/4″ are used on all other locations except the left front corner at the Roll Pin. This Cap Screw is 1 3/4″.

 

Be careful when removing the Shift Bar Housing to prevent damaging the Oil Tube with the Shift Yokes. The Slave Valve and Interlock parts must be removed prior to installing the Shift Bar Housing.

 

2022 EATON ServiceRanger 4.10 and 4.2 + Activator Free Download

 

Procedure

1.Place the Shift Bar Housing and Shift Blocks in the  Neutral position.

2.Place the Mainshaft Sliding Clutches in the Neutral position.

3.Position a new Shift Bar Housing gasket on the Shift Bar Housing mounting surface.

Note: The Slave Valve and Interlock Assembly must remain  off, until the Shift Bar Housing is installed, to avoid damaging the Interlock Pin.

4.As you install the Shift Bar Housing, make sure the Yokes fit into the corresponding Sliding Clutch slots and the Housing aligns with the Roll Pin.

5.Apply Eaton® Sealant #71205 or equivalent to the Retaining Cap Screws. Torque the Cap Screws to 35–45 lb-ft (47.45–61.01 N•m).

6.Install Interlock parts (Pin, Spring and Sleeve).

7.Install Slave Valve. Apply Loctite 242 to Cap Screw threads and torque to 8–12 lb-ft (10.85–16.30 N•m).

auto

Recent Posts

Scania Truck ALM 000463 Motion and Inclination Detector,Calibration Fault

This instruction show you guide on how to solve Scania truck motion and inclination detector,…

2 weeks ago

How to Solve JCB Excavator C130C-13 Spool Brake Solenoid Open Circuit

This instruction show you guide on how to solve JCB excavator 140 C130C-13 spool brake solenoid…

2 weeks ago

Scania Truck ALM Alarm System ALM404 Fault in the CAN Communication Solution

Scania truck fault in the CAN communication with the chassis management system (CMS),this instruction show…

4 weeks ago

Perkins Phaser/1000 Series Engine New Water Pumps Changed

The water pumps used on all Phaser/1000 Series engines have been changed. The changes to…

4 weeks ago

Deutz Engine EMR3 Request of Engine OFF Error Solution

Here is the simple instruction on how to solve Deutz engine EMR3 trouble code 48…

1 month ago

How to Use Cat ET 2025A Power Shift Pressure Test Function?

CAT ET 2025A Power Shift Pressure Test function checks whether that the proportional reducing valve is…

1 month ago