Clark ISUZU 4LE2 Tier-4 Engine Fuel Supply Pump Removal Guide

This instruction show you steps on how ot remove fuel supply pump for Clark machine with ISUZU 4LE2 Tier-4 engine.

 

Related Contents:

ISUZU E-IDSS 2024 2019 Engine Diagnostic Service System Free Download

ISUZU IDSS MX2-T Diagnostic Tool

 

Procedures:

1Battery Ground Cable Disconnect

1 Disconnect the battery ground cable from the battery.

 

2 Cooling Fan Removal

1 Remove the cooling fan from the fan pulley.

 

3 Cooling Fan Belt Removal

1 Remove the cooling fan belt from the pulley.

Note: Loosen the generator adjust bolt and remove the belt.

 

4 Fan Pulley Removal

1 Remove the fan pulley from the water pump assembly.

 

5 Generator Removal

1 Disconnect the harness connector from the generator.

2 Remove the generator from the generator bracket.

3 Remove the adjust plate from the water pump assembly.

Note: The diagram shows the 24 V – 50 A specification.

 

6 Generator Bracket Removal

1 Remove the generator bracket from the cylinder block.

 

7 Crankshaft Pulley Removal

1 Remove the crankshaft pulley from the crankshaft.

Note: Remove after stopping the crankshaft from turning.

Caution: Do not reuse the bolt and the washer.

 

8 CMP Sensor Removal

1 Disconnect the harness connector from the CMP sensor.

2 Remove the CMP sensor from the timing gear case.

3 Remove the O-ring from the CMP sensor.

 

9 Timing Gear Case Removal

1 Remove the idle gear cover from the timing gear case.

2 Remove the timing gear case from the front oil pump plate.

 

10 Fuel Pipe Removal

1 Remove the fuel pipe from the fuel supply pump and the common rail (fuel rail) assembly.

 

11 Fuel Return Pipe Removal

1 Remove the fuel return pipe from the fuel supply pump.

 

12 Fuel Supply Pump Removal

1 Disconnect the harness connector from the fuel supply pump.

2 Remove the fuel supply pump from the front oil pump plate.

Note: Remove the tightening bolts, and remove together with the bracket.

3 Remove the supply pump gear from the fuel supply pump.

4 Remove the fuel supply pump from the supply pump bracket.

Caution: Do not hold the high pressure pipe of the pump when removing the fuel supply pump.

5 Remove the O-ring from the fuel supply pump.

 

More repair cases for ISUZU engine,please refer to:ISUZU Engine Trouble Repair

auto

Recent Posts

Valtra BH Series 140-210 Trouble Internal Roll inertial Sensor Fault

This instruction show you guide on how to solve Valtra BH Series 140-210 trouble code SA…

2 days ago

Caterpillar C9 Engine Throttle Position Out of Calibration 28 91-13 Trouble Solution

This instruction show you guide on how how to solve trouble code 28 PID 91-13…

5 days ago

Magneti Marelli 1 AVB-VW ECU Pinout

Vehicles: With AP 1.6, 1.8 and 2.0 Ml engines DE 97 to 99. And for…

1 week ago

Valtra BH Series 140-210 Internal lateral Inertial Sensor Recalibration

This instruction show you guide on how to solve Valtra BH Series 140-210 trouble code SA…

1 week ago

Bendix AutoVue 3G LDW System Driver Assistance Systems (DAS) Tests

JPRO 2025V3 Driver Assistance Systems (DAS) Tests allows the editing of configuration parameters.   Related Contents:…

2 weeks ago

How to Solve PCC2300 PowerCommand Membrane Buttons Not Functioning

This instruction show you guide on how to solve PCC2300 Powercommand Membrane buttons not working.…

2 weeks ago