Heavy Equipment Repair

QSK60 G CM2358 Engine Fault 1369 Auxiliary Temperature Sensor Input 1 Circuit

QSK60 G CM2358 Engine Fault 1369 Auxiliary Temperature Sensor Input 1 Circuit  Voltage Above Normal or Shorted to High Source.

 

Related Contents:

INSITE 8.9.2 Engine Diagnostic Software

Cummings INLINE 6 Diagnostic Adapter

 

 

Code:

Fault Code: 1369
PID: P441
SPN: 441
FMI: 3/3
LAMP: Maintenance

 

Reason:

High signal voltage detected at the Original Equipment Manufacturer (OEM) auxiliary temperature circuit.

Circuit Description

The original equipment manufacturer (OEM) has the option of wiring an auxillary temperature sensor to the engine control module (ECM). Refer to the OEM service manual for information about the auxillary temperature sensor.

 

Component Location

The OEM temperature sensor input and location will vary. Refer to the OEM service manual for sensor location.

 

Conditions for Running the Diagnostics

This diagnostic runs continuously when the keyswitch is in the ON position.

 

Conditions for Setting the Fault Codes

The Engine Control Module (ECM) detected the OEM temperature signal circuit is out of range high.

 

Action Taken When the Fault Code is Active

The ECM illuminates the white MAINTENANCE lamp or flashes the amber CHECK ENGINE lamp, indicating a maintenance condition, immediately after the diagnostic runs and fails.

 

Conditions for Clearing the Fault Code

To validate the repair, start the engine and let it idle for up to 5 minutes.

The fault code status displayed by the recommended Cumming electronic service tool or equivalent will change to INACTIVE immediately after the diagnostic runs and passes.

The ECM will turn off the flashing amber CHECK ENGINE lamp / MAINTENANCE lamp immediately after the diagnostic runs and passes.

The “Reset All Faults” command in the recommended Cumming electronic service tool or equivalent can be used to clear active and inactive faults.

 

More repair case for QSK60 CM2358,please refer to QSK60 CM2358 Trouble Repair

auto

Recent Posts

How to Solve Deutz EMR3 80 / 190 Engine Speed Overrun

This instruction show you guide on how to solve Deutz EMR3 Engine speed overrun 80…

4 days ago

Doosan Stage V Machine U0632 CAN-Receive-Frame Timeout Error Solution

This instruction show you guide on how to solve Doosan Stage V machine U0632 timeout…

7 days ago

CASE IH 20 Series Combine Park Brake Piston Travel and Adjustment

This instruction show you guide on how travel and adjust park brake piston for CASE…

1 week ago

How to Replace Purge Valve for Fendt 900 Vario COM III Tractor?

Here is the instruction show you guide on how to replace purge valve for Fendit…

2 weeks ago

How to Solve JCB SPN 102, FMI 1 Boost Pressure Sensor: Pressure Below Normal

Here is the instruction show you guide on how to JCB machine SPN 102,FMI 1…

2 weeks ago

How to Install Preconcave for CLAAS Lexion 480 Combine

This instruction show you guide on how to install preconcave for CLAAS Lexion 480 combine…

2 weeks ago