Removal Procedure

1 Drain the coolant from the cooling system into a suitable container for storage or disposal.

Refer to Operation and Maintenance Manual,“Cooling System Coolant – Change” for the correct procedure.

 

2.Remove bolts (1) and remove outlet connection (2).

3 Remove joint (3) and remove water temperature regulator (4). Note the orientation of the water temperature regulator for installation.

4 Loosen the hose clamp and disconnect hose (8) from water temperature regulator housing (6).

5 Remove bolts (7) and remove water temperature regulator housing (6) from the cylinder head.

6 Remove joint (5).

 

 

Installation Procedure

1 Inspect the water temperature regulator for wear, damage and correct operation. Refer to Systems Operation,Testing and Adjusting,“Water Temperature Regulator – Test” for more information. If necessary, replace the water temperature regulator.

2 Ensure that the mating surfaces of the outlet connection, the water temperature regulator housing and the cylinder head are clean and free from damage.

3 Position bolts (7) and a new joint (5) onto water temperature regulator housing (6).

4 Position water temperature regulator housing

(6) onto the cylinder head. Tighten bolts (7) to a torque of 18 N·m (13 lb ft).

5 Install water temperature regulator (4) to water temperature regulator housing (6). Ensure the correct orientation of the water temperature regulator.

6 Position a new joint (3) and outlet connection (2) onto water temperature regulator housing (6).

7 Install bolts (1). Tighten the bolts to 18 N·m (13 lb ft).

8 Connect hose (8) to water temperature regulator housing (6). Tighten the hose clamps securely.

9 Fill the cooling system with coolant to the correct level. Refer to Operation and Maintenance Manual, “Cooling System Coolant -Change” for the correct procedure.

 

More trouble repair case for Perkins,pls refer to:Perkins Trouble Repair

 

auto

Recent Posts

How to Remove and Replace Cab Heater Controls for JCB 3CX Loader

Here is the instruction show you guide on how to remove and replace cab heater…

3 weeks ago

How to Remove Differential Gear for FENDT 900 Vario COMIII

Here is the instruction show you guide on how to remove differential gear for Fendt…

3 weeks ago

International MaxxForce 7 SPN 27 FMI 4 EGRP Signal Out of Range Low

This instruction show you guide on how to solve International MaxxsForce 7 SPN 27 FMI…

4 weeks ago

2025.08 BMW ISTA 4.54.40/4.02.14 ISTA-D Rheingold for BMW ICOM

BMW ISTA-D Rheingold 4.54.40/4.02.14 Standalone / SDP 4.02.13 / ISTA-P 3.60.0.600 free download link and…

4 weeks ago

Detroit DD13 SPN 84 FMI 3 MCM Vehicle Speed Sensor Open Circuit

This instruction show you guide on how to solve Detroit DD13 engine SPN 84 FMI…

4 weeks ago

How to Solve Caterpillar 24 PID 100-3 Oil Pressure Voltage High?

This instruction show you guide on how to repair Caterpillar 24 fault code,PID 100-3 oil…

1 month ago