Heavy Equipment Repair

Perkins 800 Series Engine Water Temperature Regulator Housing Remove and Install

This instruction show you guide on how to remove and install water temperature regulator housing.

 

Related Contents:

Perkins EST 2024A & 2023A & 2019A Software Free Download

Perkins SPI2 2018A EPC+Service Manual Free Download

 

Removal Procedure

1 Drain the coolant from the cooling system into a suitable container for storage or disposal.

Refer to Operation and Maintenance Manual,“Cooling System Coolant – Change” for the correct procedure.

 

2.Remove bolts (1) and remove outlet connection (2).

3 Remove joint (3) and remove water temperature regulator (4). Note the orientation of the water temperature regulator for installation.

4 Loosen the hose clamp and disconnect hose (8) from water temperature regulator housing (6).

5 Remove bolts (7) and remove water temperature regulator housing (6) from the cylinder head.

6 Remove joint (5).

 

 

Installation Procedure

1 Inspect the water temperature regulator for wear, damage and correct operation. Refer to Systems Operation,Testing and Adjusting,“Water Temperature Regulator – Test” for more information. If necessary, replace the water temperature regulator.

2 Ensure that the mating surfaces of the outlet connection, the water temperature regulator housing and the cylinder head are clean and free from damage.

3 Position bolts (7) and a new joint (5) onto water temperature regulator housing (6).

4 Position water temperature regulator housing

(6) onto the cylinder head. Tighten bolts (7) to a torque of 18 N·m (13 lb ft).

5 Install water temperature regulator (4) to water temperature regulator housing (6). Ensure the correct orientation of the water temperature regulator.

6 Position a new joint (3) and outlet connection (2) onto water temperature regulator housing (6).

7 Install bolts (1). Tighten the bolts to 18 N·m (13 lb ft).

8 Connect hose (8) to water temperature regulator housing (6). Tighten the hose clamps securely.

9 Fill the cooling system with coolant to the correct level. Refer to Operation and Maintenance Manual, “Cooling System Coolant -Change” for the correct procedure.

 

More trouble repair case for Perkins,pls refer to:Perkins Trouble Repair

 

auto

Recent Posts

Valtra BH Series 140-210 Trouble Internal Roll inertial Sensor Fault

This instruction show you guide on how to solve Valtra BH Series 140-210 trouble code SA…

1 month ago

Caterpillar C9 Engine Throttle Position Out of Calibration 28 91-13 Trouble Solution

This instruction show you guide on how how to solve trouble code 28 PID 91-13…

1 month ago

Magneti Marelli 1 AVB-VW ECU Pinout

Vehicles: With AP 1.6, 1.8 and 2.0 Ml engines DE 97 to 99. And for…

2 months ago

Valtra BH Series 140-210 Internal lateral Inertial Sensor Recalibration

This instruction show you guide on how to solve Valtra BH Series 140-210 trouble code SA…

2 months ago

Bendix AutoVue 3G LDW System Driver Assistance Systems (DAS) Tests

JPRO 2025V3 Driver Assistance Systems (DAS) Tests allows the editing of configuration parameters.   Related Contents:…

2 months ago

How to Solve PCC2300 PowerCommand Membrane Buttons Not Functioning

This instruction show you guide on how to solve PCC2300 Powercommand Membrane buttons not working.…

2 months ago