MotoView Set Ground Speed Limits for Doosan G420FE & G424FE Engine

The maximum allowable speed of Doosan forklifts is an optional feature that can be easily activated using the MotoView service tool. This feature is very useful to customers with indoor warehouse operations.

 

Here’s how you can activate the speed-limiting feature.

1) Install Speed control option onto the trucks

2) Set the new speed limit using the MotoView Service tool, if required.

 

HOW TO INSTALL SPEED LIMIT OPTION

1) Switch assy-pressure (D700755)

2) Jumper Harness assy (A214339)

3) Elbow (D902234)

4) O-ring (S8040061)

1.Assemble the pressure switch assy onto the main pressure port of transmission using elbow and o-ring like

 

2.Assemble the harness assy between the pressure switch and engine wiring harness.

 

How To Set New Speed Limit

Default Engine Maximum Speed

Once speed control option is assembled, the default engine maximum speed is as followed

Note:

Neutral: The inching pedal is pressed by a driver.

In-Gear: The inching pedal is NOT pressed by a driver.

Speed control option (China)

 

How to Set New Speed Limit

Maximum RPM for both the NEUTRAL state (Normal) and IN-GEAR state (Speed Limiting) are configurable using the MotoView Service Tool.

Ground Speed Select Screen of the MotoView Service Tool

 

It shows the Speed Limit screen of the MotoView service tool. The green boxes are configurable for both the NEUTRAL MAX RPM Setpoint and the IN-GEAR MAX RPM Setpoint. The pressure switch state is displayed at the bottom of the screen and labeled NEUTRAL SWITCH STATE.

 

With pushing of inching pedal, the maximum RPM for normal speed governing (Neutral State) is set at 2600.

With release of inching pedal, the maximum RPM for limited speed governing (In-Gear State) is set at 2000.

Allowable Range of RPM Limits

Software limits of both Neutral and In-Gear are displayed on the right side of the Speed Limit screen. Values that are entered in the configurable “green boxes” cannot exceed the upper limit value or fall below the lower limit value.

 

Location

 

Description

Ground Speed Limit Switch is located in the pressure port on transmission (T/M) for operating by the transmission (T/M) oil pressure change. This switch is normally opened, and then it is closed as the T/M oil pressure increases. Actually the switch is closed by increasing of the T/M oil pressure after engine cranking. And if the inching pedal is pushed by a driver the switch is opened again by decreasing of the T/M oil pressure. ECM can control the travel speed of the folk lift trucks with this switch. Also the maximum travel speed of Tier-3 and Non cert fork lift trucks is an optional feature that can be easily activated using the MotoView Service Tool. This feature may be of particular interest to customers with indoor warehouse operations.

 

[Harness Connectors]

Inspection

1.Remove the Ground Speed Limit Switch from the transmission.

2.Use an ohmmeter to check the continuity between the 1 terminal and the 2 terminal. If there is continuity, replace the Ground Speed Switch.

3.The Ground Speed Limit Switch is the ‘ON/OFF’ switch. So during the normal status the switch circuit should be open.

 

[Circuit Diagram]

auto

Recent Posts

JCB JS140 Excavator C130C-13 Spool Brake Solenoid Open Circuit Solution

This instruction show you guide on how to solve spool brake solenoid open circuit for…

3 days ago

Perkins 400A 400D Industrial Engine Crankshaft Rear Seal Remove and Install

This instruction show you guide on how to remove and install crankshaft rear seal for…

5 days ago

JPRO Diagnostic Software SCR Performance and System Test on Cummings

This instruction show you guide on how to use JPRO diagnostic to do SCR performance…

1 week ago

Yale ERP15-20VT G807 Forklift Truck Master Cylinder Removal and Disassemble Guide

Here is the instruction show you guide on how to remove and disassemble master cylinder…

2 weeks ago

How to Solve Deutz EMR3 71 / 2791 / EGRCD_SigNpl Error?

This instruction show you guide on how to solve Deutz EMR engine 71 / 2791 /…

2 weeks ago

How to Solve Allison 3000 & 4000 Gen5 P0731 Incorrect 2nd Gear Ratio?

Here is the instruction show you guide on how to repair P0731 incorrect 2nd gear ration…

3 weeks ago