International EPA07/10 Maxxforce 11/13 Engine Aftertreatment Reset by JPRO

Aftertreatment Reset provides the ability to reset the soot level after an aftertreatment component has been cleaned or replaced. It must only be performed when one of the following components has been cleaned or replaced.
o Diesel Particulate Filter (DPF)
o Diesel Oxidation Catalyst (DOC)
o Aftertreatment Fuel Injector (AFI)

 

Aftertreatment Reset is supported on:
✓ International EPA 07 and EPA 10 Maxxforce 11 and 13 engines.

 

Related Contents:

2024 JPRO Noregon Commercial Fleet Diagnostics Free Download

Noregon JPRO DLA+ 2.0 Adapter

 

Running this procedure when one of the above components has not been cleaned or replaced can result in the system becoming prematurely clogged with ash and soot, and can result in problems when performing a DPF Regeneration.
1. Select Aftertreatment Reset and press Enter or the Start button.

2. The Aftertreatment Reset dialog will be displayed.

 

NOTE: On International EPA 10 and EPA 13 engines, the Aftertreatment Reset window will not have the Test Selection options.
3. On EPA 07 International engines, select the appropriate Test Selection from the selection box. Selection options include: ‘New DPF Installed, ‘DPF Cleaned’, ‘New or Cleaned DOC’ or ‘New or Cleaned AFT Fuel Injector’.
Test Selection does not apply to EPA 10 or EPA 13 International engines.
4. Ensure all preconditions are met and select the Reset button to initiate the reset operation. Follow the instructions given on the dialog.
5. Turn off the ignition and select the Continue button (previously was the Reset button).
6. Wait for the displayed timer progress to complete. When complete, the Exit button is enabled and the instruction to ‘Please turn ignition on to re-establish communications.’ displays.
7. Turn the ignition on. Wait for communication to be re-established.
8. Once the status updates to ‘Procedure Successfully Completed’, press Exit to return to the test selection dialog.

 

More topics about JPRO Diagnostic,please refer to:JPRO Diagnostics Guide

auto

Recent Posts

Scania Truck ALM 000463 Motion and Inclination Detector,Calibration Fault

This instruction show you guide on how to solve Scania truck motion and inclination detector,…

2 weeks ago

How to Solve JCB Excavator C130C-13 Spool Brake Solenoid Open Circuit

This instruction show you guide on how to solve JCB excavator 140 C130C-13 spool brake solenoid…

2 weeks ago

Scania Truck ALM Alarm System ALM404 Fault in the CAN Communication Solution

Scania truck fault in the CAN communication with the chassis management system (CMS),this instruction show…

4 weeks ago

Perkins Phaser/1000 Series Engine New Water Pumps Changed

The water pumps used on all Phaser/1000 Series engines have been changed. The changes to…

4 weeks ago

Deutz Engine EMR3 Request of Engine OFF Error Solution

Here is the simple instruction on how to solve Deutz engine EMR3 trouble code 48…

1 month ago

How to Use Cat ET 2025A Power Shift Pressure Test Function?

CAT ET 2025A Power Shift Pressure Test function checks whether that the proportional reducing valve is…

1 month ago