Categories: Excavator Repair

How to Use DMS-5 to Calibrate Swash Plate Angle

This instruction show you guide on how to use DMS-5 diagnostic software to calibrate swash plate angle for Doosan excavator.

 

Related Contents:

Doosan Data Monitoring System DMS-5 DMS-3 Free Download

Daios Doosan EPC Excavator Part Catalog 2017 Download & Installation

 

Procedures:

Swash Plate Angle Calibration

<Pump Swash plate angle sensor calibration concept>
1. In the case of VBO, the flow rate of the pump is controlled based on the swash plate angle sensor value, so the
sensor value must be measured at the maximum/minimum of the swash plate angle and calibration to the Software
reference value for accurate flow control.
2. That is, by measuring the swash plate angle sensor output(voltage) when the pump is at the maximum/minimum
position to calibrate the maximum/minimum swash plate angle value. 3.
3. For example, theoretically, the sensor output voltage at the maximum/minimum swash plates is at 4.5/0.5V, but if
the actual sensor value is 4.4/0.4V, it will be calibrated at 4.4V and the minimum at 0.4V.

<Caution>
1. The green light meaning of the displayed value is an indication that the tolerance for mounting the pump angle
sensor is within range, meaning no calibration is required. It is recommended that the measurements be calibration for
precise control.
2. That is, click ‘APPY’ after front pump calibration, and then click ‘APPLY’ again apply after rear pump calibration to save
the calibration value for each pump.
3. If the window displaying the value with red color, the pump is suspected to be defective so please contact Doosan regional service manager

Swash Plate Angle Calibration Setting before a test

 

Swash Plate Angle Calibration Process:

1.If it’s green – Click the Save button to save the calibration value.
2.If it’s red – Recalibration is performed 2-3 times, and if it continues to be red contact your
regional service manager.If it turns to green light after 2-3 times trials during recalibration, click the Save button to save
the calibration value

1.If it’s green – Click the Save button to save the calibration value.
2.If it’s red – Recalibration is performed 2-3 times, and if it continues to be red contact your
regional service manager.If it turns to green light after 2-3 times trials during recalibration, click the Save button to save the calibration value.

 

auto

Recent Posts

How to Inspect and Clean Cylinder Block for John Deere PowerTech 9.0 OEM Engine

This instruction show you guide on how to inspect and clean cylinder block for John…

2 days ago

How to Remove and Replace Cab Heater Controls for JCB 3CX Loader

Here is the instruction show you guide on how to remove and replace cab heater…

3 weeks ago

How to Remove Differential Gear for FENDT 900 Vario COMIII

Here is the instruction show you guide on how to remove differential gear for Fendt…

4 weeks ago

International MaxxForce 7 SPN 27 FMI 4 EGRP Signal Out of Range Low

This instruction show you guide on how to solve International MaxxsForce 7 SPN 27 FMI…

4 weeks ago

2025.08 BMW ISTA 4.54.40/4.02.14 ISTA-D Rheingold for BMW ICOM

BMW ISTA-D Rheingold 4.54.40/4.02.14 Standalone / SDP 4.02.13 / ISTA-P 3.60.0.600 free download link and…

4 weeks ago

Detroit DD13 SPN 84 FMI 3 MCM Vehicle Speed Sensor Open Circuit

This instruction show you guide on how to solve Detroit DD13 engine SPN 84 FMI…

1 month ago