How to Use Deutz SerDia2010 Trip Recorder Function?

Deutz SerDia2010 trip recorder holds the record for the measured values given in SerDia2010 and counts them.It also includes load spectrum.

There are 3 different types of counters in the trip recorder:
1. Counting stage 1, an X / Y / Z or 3D chart
2. Counter stage 2 is an X / Y-value table
3. Counter stage 3/4 counts up the number of states spent only for the specific measurement..
“Confirm selection” by pressing the button of the corresponding counter is stored locally.

Related Contents:

2023 Deutz Serdia2010 v14.1.9.1 Diagnostic Software Free Download

Deutz Diagnostic Kit DECOM for Deutz Engine

 

 

Counter Stage 1:
1.Load Spectrum
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]
The structure of the bottom of the window measurement is shown as follows:

 

2.) Oil pressure trip recorder (analogous to 1)
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]
3.) Boost pressure trip recorder (analogous to 1)
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]

Counter State 2:
Counter stage 2.2 records the coolant temperature over the engine over the time (hours of
operation).

In the lower window following table is shown:

X-Value is the time [h] (upper row)
Y-Value the coolant temperature (CT) [°C] (lower row)
The counter-Level 2 diagrams are to read as follows:
-30 °C < CT < 70 °C 0,0 Hours
70 °C < CT < 85 °C 0,0 Hours
85 °C < CT < 100 °C 0 Hours –>
100 °C < CT < 115 °C 0,45 Hours –>
115 °C < CT < 130 °C 0,0 Hours –>
The following collections may vary with the connected motor / EAT System !!
Counter stage 2.2 records the boost temperature over the time.
Counter stage 2.3 records the coolant temperature over the time.
Counter stage 2.4 records the SCR-Pump pressure over the time.
Counter stage 2.5 records the injection pressure over the time.
Counter stage 2.6 records the ambient air pressure over the time.

Counter Stage 3:
For the measured values displayed in the lower window will display the time in the respective
states in seconds.

 

Counter State 4:
For the measured values displayed in the lower window will display the time in the respective
states in seconds, for example:
· Coolant temperature over limit
· Boost temperature over limit
· etc.

Notice:This function is available at Competence Class Level 2.

auto

Recent Posts

Scania Truck ALM 000463 Motion and Inclination Detector,Calibration Fault

This instruction show you guide on how to solve Scania truck motion and inclination detector,…

1 week ago

How to Solve JCB Excavator C130C-13 Spool Brake Solenoid Open Circuit

This instruction show you guide on how to solve JCB excavator 140 C130C-13 spool brake solenoid…

2 weeks ago

Scania Truck ALM Alarm System ALM404 Fault in the CAN Communication Solution

Scania truck fault in the CAN communication with the chassis management system (CMS),this instruction show…

4 weeks ago

Perkins Phaser/1000 Series Engine New Water Pumps Changed

The water pumps used on all Phaser/1000 Series engines have been changed. The changes to…

4 weeks ago

Deutz Engine EMR3 Request of Engine OFF Error Solution

Here is the simple instruction on how to solve Deutz engine EMR3 trouble code 48…

1 month ago

How to Use Cat ET 2025A Power Shift Pressure Test Function?

CAT ET 2025A Power Shift Pressure Test function checks whether that the proportional reducing valve is…

1 month ago