Here comes the solution for Doosan engine P0089 PRV reached maximum allowed opening count.
Preparation:
Doosan Data Monitoring System DMS-5 DMS-3 Free Download
2023 Doosan Diagnostic Tool DDT & G2 Scan Software Free Download
1) Overview
CODE P0089 SPN 520203 FMI 12
REASON
Monitoring the durability of the PRV (Opening time/count of PRV for wear out monitoring)
EFFECT
Torque limit : 0, 1 SVS
2) Circuit Description
Rail Pressure Signal: 236 Pin
Ground: 260 Pin
+5V supply: 211 Pin
3) Component Location
4) Condition for Running Diagnostic
Key on or Engine run
5) Condition for Setting the Fault Code
1. Opening count of PRV is more than 50 times
2. Forced to open the pressure relief valve performing a rail pressure shock according to the ECU logic
3. Forced to open the pressure relief valve performing rail pressure increase
4. PRV opening time is more than 50 times and is running engine for 300min
5. PRV opening time is longer than 300min
6) Condition for Clearing the Fault Code
1. Diagnostic Tester
2. Close the pressure relief valve performing rail pressure decrease
7) Check List
Step | Inspection | Standard Value | YES | NO |
1 | Change PRV(or Common Rail) and reset PRV parameter by DDT |
More topics for Doosan,please refer to:Doosan Trouble Repair
This instruction show you guide on how to remove second tank for CLAAS AXION 960-920…
This instruction show you guide on how to solve Doosan excavator P0408 maximum EGR rate…
Here is the instruction show you guide on how to calibrate 2403 steering valve for…
This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You…
This instruction show you guide on how to remove center joint and center frame for…
How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…