Here show the instruction show you guide on how to solve Doosan engine open circuit of throttle valve powerstage P02E0.
Related Contents:
Doosan Data Monitoring System DMS-5 DMS-3 Free Download
2023 Doosan Diagnostic Tool DDT & G2 Scan Software Free Download
1) Overview
CODE | REASON | EFFECT |
P02E0 SPN 3464 FMI 5 | Open load of throttle valve powerstage | SVS Torque Limit 25% |
2) Circuit Description
5V Supply : 234 Pin
DC Motor – : 229 Pin
GND : 240 Pin
Signal : 215 Pin
DC Motor + : 205 Pin
3) Component Location
4) Condition for Running Diagnostic
Key on or Engine run
5) Condition for Setting the Fault Code
1 Open Stop : Average Voltage is out range from 534mV to 888mV
2 Governor MAX deviation : the positive deviation of the governor is more than 15% for 1000ms
3 Governor MIN deviation : the positive deviation of the governor is more than -15% for 1000ms
6) Condition for Clearing the Fault Code
1 Open Stop : It is range from 534mV to 888mV between 240 and 215 Pin
2 Governor MAX deviation : The Governor Deviation is not going for 480ms
3 Governor MIN deviation : The Governor Deviation is not going for 480ms
7) Check List
Step | Inspection | Standard Value | YES | NO |
1 |
More topics for Doosan,please refer to:Doosan Trouble Repair
This instruction show you guide on how to remove second tank for CLAAS AXION 960-920…
This instruction show you guide on how to solve Doosan excavator P0408 maximum EGR rate…
Here is the instruction show you guide on how to calibrate 2403 steering valve for…
This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You…
This instruction show you guide on how to remove center joint and center frame for…
How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…