Detroit GHG17 Diesel Exhaust Fluid (DEF) Quantity Test will check that the correct amount of DEF fluid is delivered in a certain period of time. A fault code will normally accompany this procedure.
Related Contents:
2024.06 Detroit Diesel Diagnostic Link DDDL 8.20 8.09 Free Download
Note : Using Detroit DiagnosticLink 8.19:
A properly operating system will deliver between 108 and 132mL of DEF once the test has completed.
New doser bolts and gasket are required after running this procedure.
Test as follows:
1 Remove the vehicle side fairing to gain better access to the dosing unit.
2 Remove the three bolts securing the DEF dosing unit to the mounting plate and discard bolts. Do not disconnect the DEF lines or electrical connector.
3 Use the graduated cylinder from DEF kit W060589001900 to measure the DEF dispensed during the test.
4 Place the doser on top of the graduated cylinder with the nozzle facing downward into the cylinder.
5 Turn the ignition ON (key ON, engine OFF).
6 Connect to DiagnosticLink®.
7 From “Actions” drop-down menu, select “Aftertreatment”, then “DEF Quantity Test.”
8 Click the “Start” button to begin the “DEF Quantity Test.”
9 The test will run for four minutes; once completed, verify the amount of DEF dispensed.
More repair cases for Detroit Diesel engines,please refer to:Detroit Diesel Engine Repair
This instruction show you guide on how to solve Scania truck motion and inclination detector,…
This instruction show you guide on how to solve JCB excavator 140 C130C-13 spool brake solenoid…
Scania truck fault in the CAN communication with the chassis management system (CMS),this instruction show…
The water pumps used on all Phaser/1000 Series engines have been changed. The changes to…
Here is the simple instruction on how to solve Deutz engine EMR3 trouble code 48…
CAT ET 2025A Power Shift Pressure Test function checks whether that the proportional reducing valve is…