Bendix EC-80 Cartridge Lifetime Prediction Reset Test by JPRO

Here is the instruction show you guide on how to perform Cartridge lifetime prediction reset for Bendix EC-80 by JPRO Diagnostic Software.This test provides the ability to reset the Cartridge Lifetime Remaining value to 100% after a new air dryer cartridge has been installed.

 

Related Contents:

2024 JPRO Noregon Commercial Fleet Diagnostics Free Download

Noregon JPRO DLA+ 2.0 Adapter

 

Procedures:

1 Select Cartridge Lifetime Prediction Reset Test and press Enter or the Start Button.

2 The test dialog will be displayed.

NOTE: Reset should only be performed after a new air dryer cartridge has been installed.
3 Click the Reset button to reset the Cartridge Lifetime Remaining value to 100%. The Wetness Level and Total Air Delivered values will also be reset.
4 Selecting Additional Info will display important test and repair information, including explanations for related faults. Click Exit to close this screen.

 

Cartridge Lifetime Prediction Reset Information:

The CLP Reset should only be performed after a new air dryer cartridge has been installed. Resetting the CLP without changing the cartridge can lead to moisture and water in air system.

Cartridge Lifetime Remaining (SPN 13073) indicates between 100% for a fresh cartridge to 0% for

an expired cartridge. After CLP Reset is performed, Cartridge Lifetime Remaining will read 100%.

 

For specific instructions, see AD-HFi Service Data Sheet SD-08-12046.

The following faults are the ones related to Cartridge Lifetime Prediction and the actions to take:

Cartridge maintenance prediction pre-worn alert (Flash Code 30-1), SPN 521610, FMI 15:

This indicates the cartridge is approaching its lifetimne limit (15% lifetimne remaining or less).

Cartridge may be replaced and CLP Reset run.

 

Cartridge maintenance prediction nominal alert (Flash Code 30- 2), SPN 52610, FMI 16:

This indicates the cartridge has reached its lifetime limit or 0% lifetime remaining. Cartridge must be replaced and CLP Reset run.

 

Cartridge maintenance prediction over-worn alert (Flash Code 30-3), SPN 521610, FMI 0:

This indicates that the cartridge has been in service beyond its service lifetime. This fault also

indicates there may be water in the air system. Check reservoirs for water via drain check valves and service accordingly. Cartridge must be replaced and CLP Reset run.

 

5 When done, press the Exit button to return to the test selection dialog.

More topics about JPRO Diagnostic,please refer to:JPRO Diagnostics Guide

auto

Recent Posts

JCB JS140 Excavator C130C-13 Spool Brake Solenoid Open Circuit Solution

This instruction show you guide on how to solve spool brake solenoid open circuit for…

3 days ago

Perkins 400A 400D Industrial Engine Crankshaft Rear Seal Remove and Install

This instruction show you guide on how to remove and install crankshaft rear seal for…

5 days ago

JPRO Diagnostic Software SCR Performance and System Test on Cummings

This instruction show you guide on how to use JPRO diagnostic to do SCR performance…

1 week ago

Yale ERP15-20VT G807 Forklift Truck Master Cylinder Removal and Disassemble Guide

Here is the instruction show you guide on how to remove and disassemble master cylinder…

2 weeks ago

How to Solve Deutz EMR3 71 / 2791 / EGRCD_SigNpl Error?

This instruction show you guide on how to solve Deutz EMR engine 71 / 2791 /…

2 weeks ago

How to Solve Allison 3000 & 4000 Gen5 P0731 Incorrect 2nd Gear Ratio?

Here is the instruction show you guide on how to repair P0731 incorrect 2nd gear ration…

3 weeks ago