Bendix EC-60 EC-80 Yaw Rate and Lateral Accel. Test and Calibration
The Yaw Rate and Lateral Accel. Test and Calibration is available on:
✓ Bendix EC-60 Advanced braking systems
✓ Bendix EC-80 ESP/ESP+ braking systems
This test checks the calibration of the Yaw Rate/ Lateral Acceleration sensor when the vehicle is stationary. It also provides the ability to recalibrate the sensor if its values are found to be out of bounds.
Related Contents:
2024 JPRO Noregon Commercial Fleet Diagnostics Free Download
Procedures:
1 Select the Yaw Rate and Lateral Accel. Test and Calibration and press Enter or the Start button.
2 The test dialog will be displayed.
3 From the Sensor Readings tab observe the monitored data values and compare them to the defined acceptable ranges. Select the Graph tab to view a graph of the monitored data values.
4 Select the Calibration tab to perform recalibration of the Yaw Rate/Lateral Acceleration sensor. Important test information is displayed for review. Select the Next button to continue.
5 Click the Start button to begin the recalibration.
6 When recalibration begins the test information will be replaced with a fault display for related braking system faults. When calibration is completed a success message will be displayed. Click OK to dismiss this message.
7 If desired the recalibration can be performed again by clicking the Rerun button to return to calibration instructions.
8 When done, press the Exit button to return to the test selection dialog.
More topics about JPRO Diagnostic,please refer to:JPRO Diagnostics Guide
This instruction show you guide on how to solve Scania truck motion and inclination detector,…
This instruction show you guide on how to solve JCB excavator 140 C130C-13 spool brake solenoid…
Scania truck fault in the CAN communication with the chassis management system (CMS),this instruction show…
The water pumps used on all Phaser/1000 Series engines have been changed. The changes to…
Here is the simple instruction on how to solve Deutz engine EMR3 trouble code 48…
CAT ET 2025A Power Shift Pressure Test function checks whether that the proportional reducing valve is…